What should be checked in a trial stay before reopening a refurbished guest room?
Have someone stay in the room overnight and use it exactly as a guest would, then report against a checklist. Many faults in a refurbished room only appear during an ordinary night's use and are invisible during an inspection.
Quick Answer
Have someone stay in the room overnight and use it exactly as a guest would, then report against a checklist. Many faults in a refurbished room only appear during an ordinary night's use and are invisible during an inspection.
Use the room as a guest
Arrive as a guest, unpack, use the bathroom, sleep a full night, shower in the morning and check out.
Do not inspect it as a project team member. The purpose is to discover what a guest would experience, and that requires using the room normally.
Check the things that only appear at night
Check how dark the room is with the curtains closed, whether any indicator light is intrusive, and whether corridor light enters under the door.
Check noise: the corridor, the adjacent room, the bathroom extract, the air conditioning at night, and anything that cycles.
Check the practical details
Check that the lights can be operated from the bed, that the bedside sockets are reachable, and that the controls are understandable without instruction.
Check hot water at the times a guest would use it, the shower pressure and temperature stability, and drainage in the bathroom.
Ask for the trial stay to happen before the design is repeated across other rooms rather than after, since the value of the exercise lies in what it changes. A trial conducted once every room is finished can only produce a list of items to correct.
Report against a checklist
Report findings against a structured list covering entry, lighting, controls, bathroom, noise, temperature, storage and departure.
Have more than one person stay, since individual guests notice different things.
Repeat the trial after the findings are addressed rather than assuming the fixes worked, particularly for anything relating to noise or temperature. This finds what an inspection cannot; the technical performance of any system and its commissioning remain matters for the qualified professionals.
Need help with your property?
Discuss your project with MANZIL
Tell us where your commercial building / space is, what records you have and how it is currently being used.
WhatsApp MANZILMANZIL Approvals
Not sure which approvals apply to your property?
Explore general guidance for your property, planned work and location. Project-specific approvals still need verification.
Explore MANZIL ApprovalsExplore by property
More answers for the place you’re working on.